Single-Phase Rack-Mount Online UPS · 1–3 kVA
Energo ACS · 1–3 kVA
A rack-mount online UPS in the 1–3 kVA class for server and network cabinets. Internal or external batteries are selected according to the model and target autonomy.
Request a quoteTRStable power, suitable autonomy and a scalable system for your critical loads.

The ACS Series 1–3 kVA Online UPS provides compact rack-mount power protection for sensitive electronic equipment. Its 2U enclosure, online double-conversion technology and internal or external battery options accommodate different autonomy requirements.
1–3 kVAProduct details →
The ACS Series 6–10 kVA Online UPS provides double-conversion protection for critical rack equipment. A 4U model with internal batteries or a 2U model with external batteries is selected according to load capacity and autonomy.
6–10 kVAProduct details →
ACS Series 10, 15 and 20 kVA online UPS systems use a three-phase supply to provide stable power for critical single-phase loads. Double conversion, a 1.0 output power factor and external battery options support rack or tower installations.
Rack and Tower | 10–20 kVAProduct details →
The ACT Series provides online double-conversion protection for critical three-phase loads. Its 10–40 kVA capacity options, tower enclosure and monitoring connections support continuous power in commercial and industrial systems.
10–40 kVAProduct details →
The ACT Series is a rack-mount online UPS for critical three-phase loads. Its 10–60 kVA options, double-conversion technology and monitoring connections support servers, communications and industrial control systems.
10–60 kVAProduct details →
The ACM Series combines online double-conversion protection with a compact modular design. Different power modules allow capacity to be configured according to load requirements and growth plans.
10–180 kVAProduct details →
The ACM Series combines three-phase online power protection with a modular cabinet. Its 50 kW power modules allow capacity to be configured for current loads and future growth.
50–600 kVAProduct details →
The ACM Series provides three-phase online power protection for high-power critical loads. Its 100 kVA / 100 kW power modules allow capacity to be configured for project requirements.
100–1200 kVAProduct details →UNINTERRUPTIBLE POWER
Power failures and mains voltage fluctuations can affect servers, communications equipment and industrial controls. A correctly selected UPS supports continuity and supplies critical loads from batteries for the required duration.
EKA System considers load power, phase arrangement, target autonomy, installation space and redundancy together. Single- and three-phase online UPS options and modular systems are assessed against present project requirements and growth plans.
PRODUCT AND TECHNOLOGY
During normal operation, an online double-conversion UPS converts incoming AC to DC, then generates AC output through the inverter. This controls output voltage and frequency to provide regulated power for critical loads.
When mains power fails, batteries provide DC energy and the inverter continues supplying critical loads under suitable operating conditions. Static and maintenance bypass are considered for faults, overload and servicing. The bypass source, protection limits and transfer conditions depend on the selected model.
BATTERIES AND AUTONOMY
UPS capacity and battery runtime are separate selection criteria. Autonomy depends on actual load, battery capacity and condition, ambient temperature and system operating conditions.
Battery sizing considers whether the objective is to operate critical equipment for a defined period, bridge generator start-up or allow controlled shutdown. Internal and external battery options are assessed with installation space and maintenance requirements.
APPLICATIONS
TECHNICAL OPTIONS
Final values depend on the selected model, system configuration and site conditions.
SYSTEM ARCHITECTURE
Depending on requirements, options may include modular capacity expansion, parallel operation, redundancy, maintenance bypass, external battery cabinets and remote monitoring. Availability depends on the UPS model and system configuration.
Operating status, load level, battery information and alarms can be monitored through the local display and supported communication interfaces. SNMP, RS485 and dry contacts are selected with the interfaces and accessories available for the model.
PROJECT INPUTS
Unknown values can be clarified through site inspection and engineering before quotation.
Load list and total kW and kVA requirements.
Phase and voltage arrangements on the mains and load sides.
Required battery runtime.
Generator details and UPS operating scenario.
Initial load, growth plan and redundancy requirements.
Installation area, ambient temperature and space for battery cabinets.
Maintenance bypass and monitoring connection requirements.
TECHNICAL QUESTIONS
No. Assess kW capacity, load power factor, starting or transient loads, phase arrangement, redundancy and target autonomy together.
It may suit projects requiring capacity expansion over time or redundancy through an appropriate module arrangement. Usable load capacity must account for modules reserved for redundancy.
Runtime cannot be calculated from UPS power alone. Battery sizing must use actual load, battery capacity and operating conditions.
No. DC voltage, charging characteristics and the manufacturer-supported BMS connection must be verified for lithium battery use.